Distribution > A.R.G ElectroDesign > SatService: A.R.G ElectroDesign Protection Switch

Protection Switch

ARG Flex 2400 protection switch

The ARG FLEX 2400 is a fully managed, high availability protection switch and distribution amplifier with different interfaces including SDI, ASI, Telecom E3, DS3, RF (L-Band), STM-1 and Gigabit Ethernet.

The ARG FLEX 2400 can be programmed to switch on loss of signal and pre-determined signal deterioration such as bit error rate, frame loss or loss of synchronization and a manual switchover is possible via a front panel key, or forced by GPIs on the rear panel.

Applications

ARG 2400 series application example with ARG 1900 media combiner
  • Redundancy for Telco Links
  • 1+1 Encoder Systems
  • Modulator Protection
  • ASI Signal protection

Features

  • Telcom and G.703 Interfaces: T1, E1, E3, DS3, STM-1
  • ASI Transport stream modules
  • RF L-Band interface with low insertion loss and VSWR, 50/75 Ohm
  • 8 Port Gigabit Ethernet with two SFP and two RS232 channels
  • Optical splitter and optical protection switch modules for Single Mode 1310/1550nm
  • Manual or automatic switching
  • Programmable switching criterias such Sync Loss or BER
  • 1 HU compact rack mount chassis
  • Dual power supplies 100-240 VAC and option 36-72VDC
  • Intuitive front panel for local set-up and control
  • Web browser interface
  • SNMP capability for remote management

Switching and splitting modules

Input Protection Switch Module Active Splitter Module
ASI 2 inputs : 3 outputs 1 input : 4 outputs
RF 2 inputs : 1 output + 1 monitor output n/a
SDI   1 input : 4 outputs
T1 2 inputs : 2 outputs 1 input : 3 outputs
E1 2 inputs : 2 outputs 1 input : 3 outputs
E3 2 inputs : 2 outputs 1 input : 3 outputs
DS3 2 inputs : 2 outputs 1 input : 3 outputs
E4 2 inputs : 2 outputs 1 input : 3 outputs
STM-1 2 inputs : 2 outputs 1 input : 3 outputs
GigE Managed Ethernet Switch 2 GigE SFP, 8x Fast Ethernet

Switching criteria

Interface Module Switching Criteria Gate period Switching speed
E1 (2.048 Mbit/s) Loss of Signal
Alarm Indication Signal
250ms < 0.5 mS
E3 (34.368 Mbit/s) Loss of Signal
Alarm Indication Signal
250ms < 0.5 mS
E3 G.832 (34.368 Mbit/s) Loss of Signal
Loss of Frame Alignment
F.A. errors > 1 in 10³
250ms
250ms
1s
< 0.5 mS
DS3 (44.736 Mbit/s) Loss of Signal
Loss of Frame Alignment
F.A. errors > 1 in 10³
250ms
250ms
1s
< 0.5 mS
STM-1 (44.736 Mbit/s) Loss of Signal
Loss of Frame Alignment
F.A. errors > 1 in 10³
250ms
250ms
1s
< 0.5 mS
ASI Loss of Signal
Loss of MPEG
1s
1s
< 0.5 mS
RF External control or ganged with other module N/A < 3 mS